Industrial Online pH/ORP Analyzer
Contact Info
- Add:上海市嘉定区银裕路A栋二层, Zip:
- Contact: 罗先生
- Tel:021-59996866
- Email:chinainfo@fesks.com.cn
Other Products
Detailed Introduction of FSPH 5280 Online pH/ORP Analyzer
The Fesks Online pH/ORP Meter FSPH 5280 adopts an imported new-generation microcontroller chip, specifically designed for online monitoring in industrial water treatment. It is a highly intelligent, stable, and easy-to-operate smart controller. When paired with the corresponding KSPH series pH/ORP electrodes for specific field conditions, it effectively enhances measurement accuracy and extends the electrode's service life.
Product Features
▶ 144×144 standard industrial instrument design
▶ Corrosion-resistant, anti-fouling, easy-to-clean metal texture process
▶ Imported chip components ensure stable and reliable measurement
▶ Large-screen LED backlit LCD display showing pH/ORP value, temperature, time, current, and relay status
▶ 2 channels of 4~20 mA current output, with customizable corresponding values
▶ One multi-function relay with cleaning, periodic alarm, and error alarm functions
▶ 2 sets of independent relays for Hi/Lo alarm points, with upper and lower limit control
▶ Supports RS485 Modbus RTU standard protocol
▶ Historical curve, measurement data storage, and query function (500,000 data sets)
▶ Automatic/manual calibration, manual/automatic temperature compensation, and other functions
Technical Parameters
Model | FSPH 5280-pH/ORP | |
Function | pH | ORP |
Measurement Range | -2.00 - +16.00 pH | -2000mV- +2000mV |
Measurement Resolution | 0.01pH | 1mV |
Measurement Accuracy | ±0.01pH | ±1mV |
Temperature Compensation Method | Pt-1000/NTC10K | |
Temperature Measurement Range | -10.0 ~ +130.0℃ | |
Temperature Compensation Range | -10.0 ~ +130.0℃ (Manual/Automatic) | |
Temperature Resolution | 0.1℃ | |
Temperature Accuracy | ±0.2℃ | |
Operating Environment Temperature | 0 ~ +70℃ | |
Storage Environment Temperature | -20 ~ +70℃ | |
Humidity | 10~90% Relative Humidity | |
Input Impedance | >10¹² Ω | |
Display | Large dot-matrix LCD with LED backlight, multiple values displayed simultaneously | |
Language Selection | English/Simplified Chinese/Traditional Chinese | |
Power Supply | 90~260VAC,50/60Hz, Power Consumption <5W; 24VDC Optional | |
pH/ORP Current Output 1 | Isolated 4-20mA output, max load 500Ω, programmable measurement value | |
Temperature Current Output 2 | Isolated 4-20mA output, max load 500Ω, programmable measurement value | |
Current Output Accuracy | ±0.05 mA | |
Digital Output | RS485 Modbus RTU Standard Protocol | |
Communication Rate | 9600/19200/38400 | |
Alarm Output/Contact Capacity | 2 sets of independent relays for Hi/Lo alarm points, with hysteresis setting, 5A/250VAC/30VDC | |
Cleaning Setting | Time: 1 to 1000s; Interval: 0.1 to 1000.0h (adjustable) | |
One Multi-function Relay | Cleaning/Periodic Alarm/Error Alarm | |
Relay Delay Action | 0-120s | |
Data Recording | . 2e||
USB Interface | Data download and software update (optional) | |
Protection Level | IP65 | |
Instrument Dimensions | 144mm*144mm*108mm | |
Panel Cutout Dimensions | 138*138mm | |
Installation Method | Panel mounting/Wall mounting/Pipeline mounting | |
Weight | 0.87Kg | |
Electrode Selection
KS Series pH/ORP Electrodes
KSPH 130 Electrode Suitable for pH measurement in general sewage and tap water | KSPH 130B Electrode Suitable for pH measurement in heavy metal, organic, high chlorine, ammonia, and chemical wastewater |
KSPH 155T Electrode Suitable for pH measurement in desulfurization | KSPH 160HF Electrode Suitable for pH measurement in water containing hydrofluoric acid |
KSPH 165G Electrode Suitable for pH measurement in general high-temperature media | KSPH 170GF Electrode Suitable for pH measurement in high-temperature fermentation |
KSPH 170GH Electrode Suitable for pH measurement in high-temperature heavy metal, organic, high chlorine, ammonia, and chemical applications | MODEL:KSPH180D Electrode Suitable for pH measurement in low-temperature media |
KSPH 185C Electrode Suitable for pH measurement in low conductivity water such as pure water and RO water | MODEL:KSOP 190 Electrode Suitable for ORP measurement in general water treatment and highly polluted wastewater |
Instrument Applications
Widely used in sewage treatment, tap water, pure water, circulating water, boiler water systems, as well as in electronics, electroplating, printing and dyeing, chemical, food, pharmaceutical, and other process industries.
Ordering Information
Model | Ordering Code | Description |
FSPH 5280 | 50-5280-00 | Intelligent pH/ORP Controller |
KSPH 130 | 22-0130-00 | pH Electrode, for more application-specific electrode models, please refer to the selection guide |
KSOP 190A | 22-0190-10 | ORP Gold Electrode -2000mV~ +2000mV |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | Fesks/上海费思克 |
| Spec: | FSPH 5280 |
| Stock: | 1000 |
| Manufacturer: | |
| Origin: | China / Shanghai / Jiadingqu |